Please install the Flash player in order to view a fully-functional version of this page. Click here to download the free plugin.
Home
About Us
Support
News and Events
Shopping Cart
Contact Us
Product Index
CL-5610 - NEW ! Non-contact thickness meter 0.1um resolution
The CL-5600 Series non-contact thickness meters use an electrostatic capacitance-type gap detector to measure conductors, semiconductors and insulators. The VE Series electrostatic capacitance-type gap detectors have shown proven results as non-contact electrostatic capacitance-type sensors, and enable high-accuracy, stable thickness measurement using easy operations. The CL-5600 Series offers both a conductor/semiconductor measurement function that uses two sensors (standard) and an insulator measurement function (option: CL-0300) that uses one sensor. Featuring a new outward appearance and enhanced functions, they utilize the revamped electrostatic capacitance-type converters, the VE Series gap detectors. The measurement range has been expanded, and an easy-to-read fluorescent display has been utilized for the display unit. Moreover, the separation of the gap converter from the main unit enables the addition of an analog output, a comparator function (option: CL-0100) and a high-resolution display function (option: CL-0200) for even more flexibility and improved ease of use.

  • The high-resolution calculation function enables a resolution at 0.02um by using VE-5010 with optional CL-0200.
  • The gap measurement range has been increased considerably (Maximum 8 mm when VE-8020 is used.).
  • The length of the cable between the sensor and the gap converter is 1.5 m.
  • The CL-5600S features separate gap converters (CL-0420). The length of the cable between each gap converter and the main unit is 2.5 m as standard specification (Max. 10 m is possible on request as an option.).
  • An easy-to-read vacuum fluorescent display has been utilized at the display unit.
  • The RS-232C interface connection enables connection to a printer.
  • Analog and comparator output functions are both provided as optional CL-0100.
  • A function for measuring the thickness of conductors and semiconductors is provided as standard, while a function for measuring the thickness of insulators is provided as optional CL-0300.
  • RoHS Compliant
Measures Thickness, gaps
Display Vacuum fluorescent display; either 2-row display or 1-row display (large character size) can be selected.
Display Mode ABS: Measured values DEVI: Deviation values (Measured values ûreference values) Maximum, Minimum, Maximum ûMinimum
Resolution Depends on which sensors are used. 0.1, 0.5, 1, 2 um (0.02, 0.05, 0.2, 0.5, 1um by using optional CL-0200 *2)
Parameter settings by key operation on the panel can be stored in the internal memory and held in the power-off memory
Sampling Rate 20 ms
Averaging Moving mean, 1 to 64 times
Real-time data processing Max., min., max.-min. values of measuring data are displayed in real time Data initialized at the start and held at the stop.
Interface RS-232C (Cable: AX-5022/Sold separately)
Output Comparator function (Option: CL-0100 ) 3-CH output , Analog output (Option: CL-0100 ) Thickness, Gap A, B (linearity ±0.2% F.S./10% to 100% F.S.)
Operating temperature 0 to +40°C
Humidity 20 to 80% RH
Power supply 100 to 240 VAC, 50/60 Hz
Outer dimensions 210(W) mm x 99 (H) mm x 276(D) mm
Weight 4.5kg


Some great application materials that can be measured with great accuracy :   Metal plates Steel, aluminum, stainless steel, etc   Silicon Wafers Can be measured in the same way as metal plates.   Copper-foil laminated boards The thickness of both surfaces can be measured prior to etching.   Pastes such as battery pole plates prior to firing.   Carbon plates Plates which include a large amount of the carbon material used for gaskets, etc.